<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
	<record>
		<datafield tag="980" ind1=" " ind2=" ">
			<subfield code="a">CONF</subfield>
		</datafield>
		<datafield tag="970" ind1=" " ind2=" ">
			<subfield code="a">millan:2007:embs/IDIAP</subfield>
		</datafield>
		<datafield tag="245" ind1=" " ind2=" ">
			<subfield code="a">Vibrotactile Feedback in the Context of Mu-Rhythm based BCI</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Cincotti, F.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Kauhanen, L.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Aloise, F.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Palomäki, T.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Caporusso, N.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Jylänki, P.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Mattia, D.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Babiloni, F.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Vanacker, G.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Nuttin, Marnix</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Marciani, M. G.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Millán, José del R.</subfield>
		</datafield>
		<datafield tag="856" ind1="4" ind2="0">
			<subfield code="i">EXTERNAL</subfield>
			<subfield code="u">http://publications.idiap.ch/attachments/reports/2007/millan_2007_embs.pdf</subfield>
			<subfield code="x">PUBLIC</subfield>
		</datafield>
		<datafield tag="711" ind1="2" ind2=" ">
			<subfield code="a">Proceedings of the 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</subfield>
		</datafield>
		<datafield tag="260" ind1=" " ind2=" ">
			<subfield code="c">2007</subfield>
			<subfield code="a">Lyon, France</subfield>
		</datafield>
		<datafield tag="771" ind1="2" ind2=" ">
			<subfield code="d">August 2007</subfield>
		</datafield>
		<datafield tag="520" ind1=" " ind2=" ">
			<subfield code="a">Brain-Computer Interfaces (BCIs) need an uninterrupted flow of feedback to the user, which is usually delivered through the visual channel. Our aim is to explore the benefits of vibrotactile feedback during usersïÂ¿Â½ training and control of EEG-based BCI applications. An experimental setup for delivery of vibrotactile feedback, including specific hardware and software arrangements, was specified. We compared vibrotactile and visual feedback, addressing the performance in presence of a complex visual task on the same (visual) or different (tactile) sensory channel. The preliminary experimental setup included a simulated BCI control. in which all parts reflected the computational and actuation process of an actual BCI, except the souce, which was simulated using a ïÂ¿Â½noisyïÂ¿Â½ PC mouse. Results indicated that the vibrotactile channel can function as a valuable feedback modality with reliability comparable to the classical visual feedback. Advantages of using a vibrotactile feedback emerged when the visual channel was highly loaded by a complex task.</subfield>
		</datafield>
	</record>
</collection>