<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
	<record>
		<datafield tag="980" ind1=" " ind2=" ">
			<subfield code="a">CONF</subfield>
		</datafield>
		<datafield tag="970" ind1=" " ind2=" ">
			<subfield code="a">Chan_ISBI16_2016/IDIAP</subfield>
		</datafield>
		<datafield tag="245" ind1=" " ind2=" ">
			<subfield code="a">A Point-Spread-Function-Aware Filtered Backprojection Algorithm for Focal-Plane-Scanning Optical Projection Tomography</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Chan, Kevin G.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Liebling, Michael</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">deconvolution</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">filtered backprojection</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">optical microscopy</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">Optical projection tomography</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">point-spread-function</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">tomography.</subfield>
		</datafield>
		<datafield tag="711" ind1="2" ind2=" ">
			<subfield code="a">2016 IEEE International Symposium on Biomedical Imaging</subfield>
		</datafield>
		<datafield tag="260" ind1=" " ind2=" ">
			<subfield code="c">2016</subfield>
		</datafield>
		<datafield tag="520" ind1=" " ind2=" ">
			<subfield code="a">Traditional optical projection tomography requires the use of low numerical aperture objectives in order to achieve a large depth of field and approximate parallel projection geometry. However, low NA objectives suffer from poor resolution, resulting in blur in the reconstructed image. In this paper, we present a modified filtered backprojection method suitable for focal-plane-scanning optical projection tomography (FPSOPT), where each projection is obtained by scanning through focal planes during collection. We show that FPS-OPT has an exact inversion formula akin to a filtered backprojection, but that incorporates the system’s point-spread-function to recover a deblurred 3D volume. With simulations, we demonstrate that FPS-OPT permits the use of high numerical aperture objectives that lead to more accurate images. We further illustrate the technique on experimentally acquired data from a fluorescently-labeled zebrafish larva, which shows that our approach reduces out-of-focus blur.</subfield>
		</datafield>
	</record>
</collection>