<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
	<record>
		<datafield tag="980" ind1=" " ind2=" ">
			<subfield code="a">ARTICLE</subfield>
		</datafield>
		<datafield tag="970" ind1=" " ind2=" ">
			<subfield code="a">Chan_IEEETRANS.COMPUT.IMAG._2016/IDIAP</subfield>
		</datafield>
		<datafield tag="245" ind1=" " ind2=" ">
			<subfield code="a">Simultaneous temporal superresolution and denoising for cardiac fluorescence microscopy</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Chan, Kevin G.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Streichan, Sebastian J.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Trinh, Le A.</subfield>
		</datafield>
		<datafield tag="700" ind1=" " ind2=" ">
			<subfield code="a">Liebling, Michael</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">Fluorescence Microscopy</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">image denoising</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">image reconstruction</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">motion blur</subfield>
		</datafield>
		<datafield tag="653" ind1="1" ind2=" ">
			<subfield code="a">Temporal superresolution</subfield>
		</datafield>
		<datafield tag="856" ind1="4" ind2="0">
			<subfield code="i">EXTERNAL</subfield>
			<subfield code="u">http://publications.idiap.ch/attachments/papers/2016/Chan_IEEETRANS.COMPUT.IMAG._2016.pdf</subfield>
			<subfield code="x">PUBLIC</subfield>
		</datafield>
		<datafield tag="773" ind1=" " ind2=" ">
			<subfield code="p">IEEE Transactions on Computational Imaging</subfield>
			<subfield code="x">2333-9403</subfield>
		</datafield>
		<datafield tag="260" ind1=" " ind2=" ">
			<subfield code="c">2016</subfield>
		</datafield>
		<datafield tag="500" ind1=" " ind2=" ">
			<subfield code="a">in press</subfield>
		</datafield>
		<datafield tag="856" ind1="4" ind2=" ">
			<subfield code="u">http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7488256</subfield>
			<subfield code="z">URL</subfield>
		</datafield>
		<datafield tag="024" ind1="7" ind2=" ">
			<subfield code="a">10.1109/TCI.2016.2579606</subfield>
			<subfield code="2">doi</subfield>
		</datafield>
		<datafield tag="520" ind1=" " ind2=" ">
			<subfield code="a">Due to low light emission of fluorescent samples, live fluorescence microscopy imposes a tradeoff between spatiotemporal resolution and signal-to-noise ratio. This can result in images and videos containing motion blur or Poisson-type shot noise, depending on the settings used during acquisition. Here, we propose an algorithm to simultaneously denoise and temporally super-resolve movies of repeating microscopic processes that is compatible with any conventional microscopy setup that can achieve imaging at a rate of at least twice that of the fundamental frequency of the process (above 4 frames per second for a 2 Hz process). Our method combines low temporal resolution frames from multiple cycles of a repeating process to reconstruct a denoised, higher temporal resolution image sequence which is the solution to a linear program that maximizes the consistency of the reconstruction with the measurements, under a regularization constraint. This paper describes, in particular, a parallelizable superresolution reconstruction algorithm and demonstrates its application to live cardiac fluorescence microscopy. Using our method, we experimentally show temporal resolution improvement by a factor of 1.6, resulting in a visible reduction of motion blur in both on-sample and off-sample frames.</subfield>
		</datafield>
	</record>
</collection>