CONF Rodrigue_BSA_2026/IDIAP CitySim against DESTEST: a validation of Building and District Heating Network simulation Rodrigue, Dubon Kämpf, Jérôme Building simulation destest district heating Open-access modelling tools EXTERNAL https://publications.idiap.ch/attachments/papers/2026/Rodrigue_BSA_2026.pdf PUBLIC Free University of Bozen-Bolzano - BSA Conference Proceedings Bozen-Bolzano 2026 The decarbonization of urban areas requires reliable and precise enough urban energy modeling tools that are capable of simulating the complex behaviors of both individual buildings and those integrated within district energy systems. These tools require rigorous validation and benchmarking to ensure predictive accuracy and general usability. This paper presents the validation of CitySim, an open-access and open-source urban energy modeling tool, under the District Energy Simulation Test (DESTEST) framework. The DESTEST framework comprises a series of Common Exercises (CE) designed to evaluate building thermal dynamics and District Heating Network (DHN) modeling capabilities by comparing several modeling tools’ predictions. In this study, CitySim’s building energy performance is benchmarked against established modeling tools, including EnergyPlus, TRNSYS, and Modelica-based libraries (AixLib and Buildings). For buildings’ thermal dynamics, CitySim employs a simplified thermal resistance-capacitance (RC) model, while for the DHN behaviour it uses a steady-state approach. Results show that CitySim’s building dynamics predictions (Buildings CE-1) closely align with those generated by EnergyPlus. Furthermore, CitySim achieves promising performance on the network simulation, notably reaching an 85.6% accuracy with the DHN steady-state common exercise (Network CE-0), outperforming all other participating tools. These findings validate CitySim’s robustness and accuracy on the DESTEST’s case studies, relative to traditional and commercial modeling software. Future work will focus on refining the building CEs and extending CitySim’s capabilities to include the DHN thermal dynamics modeling which would allow its performance evaluation with the dynamic common exercise (Network CE-1).